Fluke Ti50 and Ti55 IR FlexCam® Thermal Imagers
Dowload info sheet
The professional's choice when demanding the highest sensitivity
Choose the Fluke Ti5x models when you need the best images. They feature 320 x 240 detectors with industry leading thermal sensitivity (0.05 °C NETD) for high resolution, ultra high-quality images. In addition, with a 60 Hz detector acquisition rate temperatures are displayed live on the large 5-inch color display.
The FT models feature the innovative IR-Fusion technology. IR-Fusion captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect components and enable the repair to be done right the first time. To find out more select IR-Fusion on the side navigation of this page.
Typical applications
Choose the Fluke Ti5x models when you need the best images. They feature 320 x 240 detectors with industry leading thermal sensitivity (0.05 °C NETD) for high resolution, ultra high-quality images. In addition, with a 60 Hz detector acquisition rate temperatures are displayed live on the large 5-inch color display.
The FT models feature the innovative IR-Fusion technology. IR-Fusion captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect components and enable the repair to be done right the first time. To find out more select IR-Fusion on the side navigation of this page.
Typical applications
- Predictive maintenance - Identify electrical and mechanical problems before they cause failure
- Power/utilities - Real-time analysis of substations, transmission lines and equipment
- Process monitoring - Real-time observation to ensure efficient and safe operation
- Research and development - Quantify heat patterns to improve product designs
- Electronic design - Close up circuit board analysis
- Heavy duty carrying case
- 2 rechargeable battery packs
- Battery charger
- AC adapter (for Ti55 model only)
- Video cable
- 512 MB compact flash card
- Compact flash card reader and USB cable
- PCMCIA compact flash card reader
- Neck strap
- SmartView reporting and analysis software on CD
- User manual on CD
- Calibration certificate
Specifications | Fluke Ti45 | Fluke Ti40 |
Imaging performance | ||
Thermal | ||
Field of view (FOV) | 23° horizontal x 17° vertical | |
Spatial resolution (IFOV) | 1,30 mrad | |
Min focus distance | 0,15 m | |
Thermal sensitivity (NETD) | <=0,05 °C 30 °C-on | <=0,07 °C 30 °C-on |
Detector data acquisition / Image frequency | 60 Hz/30 Hz | |
Focus | SmartFocus; one finger continuous focus | |
IR digital zoom | 2x, 4x, 8x | 2x |
Detector type | 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer with 25 micron pitch | |
Spectral band | 8ľm to 14ľm | |
Digital image enhancement | Automatic full-time enhanced | |
Visual (Fusion models only) | ||
On-camera operating modes | Full Thermal, full visual light or merged thermal-visual images. Picture-in-Picture | |
Visible light camera | 1280 x 1024 pixels, full color | |
Visible light digital zoom | 2x, 4x, 8x | 2x |
Temperature measurement | ||
Mérési hőmérsékleti tartomány | -20 °C -> 600 °C in 3 ranges |
-20 °C -> 350 °C in 2 ranges |
Range 1: -20 °C -> 100 °C |
Range 1: -20 °C -> 100 °C |
|
Range 2: -20 °C -> 350 °C |
Range 2: -20 °C -> 350 °C |
|
Range 3: 250 °C -> 600 °C |
- | |
Accuracy | ą2°C or 2 % (whichever is greater) | |
Measurement modes | Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm above and below | Centerpoint, center box (area min/max, average) |
Emissivity correction | 0.1 -> 1.0 (0.01 increments) | |
Image presentation | ||
Digital display | 5" large high-resolution digital display | |
LCD backlight | Sunlight readable color LCD | |
Video output | RS170 EIA/NTSC or CCIR/PAL composite video | |
Palettes | Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted | |
Optional lenses | ||
54 mm Telephoto lens | High precision Germanium lens | |
Field of view (FOV) | 9° horizontal x 6° vertical | |
Spatial resolution (IFOV) | 0,47 mrad | |
Min focus distance | 0,6 m | |
10.5 mm wide angle lens | High precision Germanium lens | |
Field of view (FOV) | 42° horizontal x 32° vertical | |
Spatial resolution (IFOV) | 2,45 mrad | |
Min focus distance | 0,3 m | |
Image and data storage | ||
Storage medium | Compact flash card stores over 1000 IR images (512 MB card standard) | |
File formats supported | 14 bit measurement data included. Exportable JPEG, BMP, PCX, PNG, PSD. | |
Interfaces and software | ||
Interface | Compact flash card reader included | |
Software | SmartView; Full analysis and reporting software included | |
Laser (IR-Fusion models only) | ||
Classification | Class II | |
Laser targeting | Laser dot visible on screen when blending thermal and visible image | |
Controls and adjustments | ||
Set-up controls | Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low) | |
Image controls | Level, span, auto adjust (continuous/manual) | |
On-screen indicators | Battery status, target emissivity, background temperature and real time clock | |
Power | ||
Battery type | Li-Ion smart battery, rechargeable, field-replaceable | |
Battery operating time | 3 hours continuous operation (2 hours for models with IR-Fusion) | |
Battery charging | 2 bay intelligent charger powered via AC outlet | |
AC operation | AC adapter 110/220 VAC, 50/60 Hz | |
Power saving | Automatic shutdown and sleep modes (user specified) | |
Environmental and mechanical design | ||
Operating temperature | -10°C -> +50 °C | |
Storage temperature | -40°C -> +70 °C | |
Relative humidity | Operating and storage 10% to 95%, non-condensing | |
Water and dust resistant | IP54 | |
Weight (including batteries) | 1.95 kg (4.3 lbs) | |
Camera size (HxWxD) | 162 x 262 x 101 mm (6.5" x 10.5" x 4.0") | |
Other | ||
Warranty | 2 years |
Features | Ti55 FT | Ti55 | Ti50 FT | Ti50 |
High resolution, low noise VOx detector for high quality images | 320x240 | |||
Temperature range to cover broad industrial applications | -20 °C +600 °C | -20 °C +350 °C | ||
High temperature option | 1200 °C | |||
High thermal sensitivity for viewing even the smallest temperature differences | <= 0,05 °C | <= 0,07 °C | ||
180° articulating flexible lens to view images in every situation | · | · | · | · |
Choice of 3 interchangeable lenses to cover every application | · | · | · | · |
Large 5" high contrast color LCD for a clear picture independent of lighting conditions | · | · | · | · |
Fully radiometric for detailed temperature analysis and tracking | · | · | · | · |
SmartFocus for best image quality and accurate temperature measurements | · | · | · | · |
Windows CE based menu structure for ease of use | · | · | · | · |
Personalized instrument set-up for multiple use | · | · | · | · |
CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data | · | · | · | · |
SmartView reporting and analysis software included | · | · | · | · |
AutoCapture for making intermittent problems visible | · | · | ||
On-board analysis functions | · | · | ||
User defined text annotations for simplified reporting | · | · | ||
Built-in visible light (digital) camera | · | · | ||
IR-Fusion blending thermal and visible light images to easily pinpoint suspect components | · | |||
IR/Visible Alarm function | · | |||
Laser pointer for easy targeting | · | · | ||
Flash and torch light for high quality images in dark environments | · | · |